2.patternD irng:=[Book1]1!(1,3) format:=time display:=1 tfrom:=0.41666666666666669 tto:=0.625 inc:=30 unit:=min onerepeat:=3 seqrepeat:=2;
//generate regular time data with format HH and fill to column 1 to 3 in Book1 Sheet1.
Display Name
|
Variable Name
|
I/O and Type
|
Default Value
|
Description
|
Input
|
irng
|
Input
Range
|
<active>
|
Specifies the range of data columns you would like to fill values to.
|
Format
|
format
|
Input
int
|
0
|
Specify the format of generated data.
Option list:
- 0:Date
- The values in generated dataset will be date format.
- 1:Time
- The values in generated dataset will be time format.
|
Display
|
display
|
Input
int
|
0
|
Specify the display format of the date/time data. The option index number can be found from the drop-down list of Display in the patternD dialog box. Index number starts from 0.
|
Custom Display
|
custom
|
Input
string
|
<unassigned>
|
This variable is only available when custom display is chosen for display(i.e. if format is date, display should be 21 and if format is time, display should be 17. This variable specifies the custom format of the date/time data. See the custom date format page for details.
|
From
|
from
|
Input
double
|
<unassigned>
|
This variable is only available when the format is set to Date. It is used to specify the Julian date for the starting date of the generated sequence. When opening the dialog from the menu, the default value follows the current system date.
|
To
|
to
|
Input
double
|
<unassigned>
|
This variable is only available when the format is set to Date. It is used to specify the Julian date for the ending date of the generated sequence. When opening the dialog from the menu, the default value is ten days after system date.
|
From
|
tfrom
|
Input
double
|
<unassigned>
|
This variable is only available when the format is set to Time. It is used to specify the starting time of the generated sequence. Where 0 means 00:00 and 1 means 24:00. When opening the dialog from the menu, the default value is 00:00.
|
To
|
tto
|
Input
double
|
<unassigned>
|
This variable is only available when the format is set to Time. It is used to specify the ending time of the generated sequence. Where 0 means 00:00 and 1 means 24:00. When opening the dialog from the menu, the default value is the current system time.
|
Increment
|
inc
|
Input
double
|
1
|
Specify the increment within the generated data sequence. If the increment value is not an integer, it will be rounded to the next integer.
|
Increment Unit
|
unit
|
Input
int
|
2
|
Specify the unit for the Increment value.
Option list:
- sec:Second{0}
- min:Minute{1}
- hour:Hour{2}
- day:Day{3}
- week:Week{4}
- mon:Month{5}
- year:Year{6}
|
Mode
|
mode
|
Input
int
|
0
|
Specify how the generated data should be arranged.
Option list:
- 0:Repeat
- The values in the generated data sequence will be filled to the selected column(s) by ascending/descending order (When Inc is positive, will be in ascending order; when it is negative, will be in descending order). It is also possible to define the repeat times for each value and the whole sequence(onerepeat and seqrepeat) in the generated dataset to determine the dataset size.
- 1:Random
- For each cell in the selected column, one value randomly picked from the generated data sequence will be filled into this cell. You can specify the value of size as the size of the generated dataset.
|
Repeat Times for Each Value
|
onerepeat
|
Input
int
|
1
|
This variable is only controllable when the Mode variable is 0:Repeat. It specifies how many times each value repeats itself in the generated data sequence.
|
Repeat Times for The Sequence
|
seqrepeat
|
Input
int
|
1
|
This variable is only controllable when the Mode variable is 0:Repeat. It specifies how many times each whole data sequence repeats itself in the generated dataset.
|
Total Number of Whole Set
|
size
|
Input
int
|
10
|